Справочник электронных компонентов

Транзистор 2SK2342

2SK2342 - Транзистор полевой MOSFET структуры N

Основные характеристики:

Транзистор 2SK2342 можно заменить на:

НАЗВАНИЕ ТИП СТР. Pd, Вт Vds, В Vgs, В Vgsth, В Id, А Rds, Ом Qg, нКл Tr, нС Ci, пФ Tj, гр.Ц КОРПУС
12N06 SMD N 30 60 20 - 12 0.08 - 35 75 150 TO-252
12N06Z SMD N 30 60 20 - 12 0.08 - 35 75 175 TO-252
12N10 SMD и PTH N 73 100 20 - 12 0.15 - 7 90 150 TO-220,TO-251,TO-252
2SK1270 PTH N 10 60 20 - 2 0.3 - 12 70 150 TO-126
2SK3022 SMD N 10 60 20 - 5 0.13 - 30 90 150 TO-252
2SK3335 PTH N 15 60 20 - 8 0.15 - 15 75 150 TP
2SK3411 PTH N 15 60 20 - 9 0.122 - 10 90 150 TP
2SK3449 PTH N 10 60 20 - 4.8 0.32 - 3.2 35 150 TO-126ML
2SK3611 PTH N 25 250 30 - 10 0.2 - 2.7 88 150 TO-220F
2SK3611-01MR PTH N 37 250 30 - 14 0.26 - 2.7 88 150 TO-220F
2SK3913-01MR PTH N 37 250 30 - 14 0.28 - 3 90 150 TO-220F
630A SMD и PTH N 83 200 30 - 9 0.25 - 10.7 51.5 150 TO-251,TO-252
6N10 SMD N 16 100 20 - 6.5 0.16 - 30 80 150 TO-252,SOT-223
AFN1520 PTH N 75 100 20 2 7 0.32 2.7 8 40 150 TO-220
AFN1530 PTH N 75 100 20 2.5 15 0.115 10 8 50 150 TO-220
AFN3316W SMD N 17 60 20 2.5 8 0.14 6 6 30 150 DFN3X3-8L
AFN9530 PTH N 75 90 20 2.5 15 0.078 10 10 80 150 TO-220
AFN9910 SMD N 40 100 20 2 6.5 0.32 2.7 8 40 150 TO-252
AFN9977 SMD N 40 60 20 2.5 12 0.118 6 6 50 150 TO-252
AFN9987 SMD N 40 90 20 2.5 15 0.075 10 10 80 150 TO-252
AFN9997 SMD N 40 100 20 3 8 0.12 10 8 50 150 TO-252
AM20N06-90I PTH N 50 60 20 1 19 0.094 5.1 9 59 150 TO-251
AM20N10-115D SMD N 50 100 20 1 17 0.115 10 5 66 175 TO-252
AM20N10-180D SMD N 50 100 20 1 14 0.18 9 5 56 150 TO-252
AM20N10-250D SMD N 50 100 20 3.5 11 0.28 3.8 3.9 40 175 TO-252
AM20N15-250D SMD N 50 150 20 1 10 0.255 16.7 34 86 175 TO-252
AOB256L SMD N 83 150 20 2.8 19 0.085 - 5 61.5 175 TO-263
AOD2210 SMD N 100 200 20 2.5 18 0.105 - 10 74 175 TO-252
AOD256 SMD N 83 150 20 2.8 19 0.085 - 5 61.5 175 TO-252
AOD2922 SMD N 17 100 20 2.7 7 0.14 - 3 19 175 TO-252
AOD4454 SMD N 100 150 20 4.6 20 0.094 - 5.5 70 175 TO-252
AOD446 SMD N 20 75 25 3 10 0.14 - 2.3 51 175 TO-252
AOD474 SMD N 28.5 75 20 2.4 10 0.13 - 3.5 30 175 TO-252
AOD474A SMD N 28.5 75 16 1.6 10 0.13 - 3.5 30 175 TO-252
AOD474B SMD N 28.5 75 20 2.3 10 0.132 - 3 30 175 TO-252
AOD478 SMD N 45 100 20 2.8 11 0.14 - 3 29 175 TO-252
AOD498 SMD N 45 100 20 2.3 11 0.14 - 3 31.5 175 TO-252
AOI2210 PTH N 100 200 20 2.5 18 0.105 - 10 74 175 TO-251A
AOI478 PTH N 45 100 20 2.8 11 0.14 - 3 29 175 TO-251A
AON6484 SMD N 25 100 20 2.7 12 0.079 - 2.5 55 150 DFN5X6
AON6486 SMD N 31 100 20 2.8 10 0.14 - 3 27 150 DFN5X6
AON7446 SMD N 16.7 60 20 3.3 8 0.145 - 1.5 25 150 DFN3X3
AON7452 SMD N 17 100 25 4.7 5.5 0.31 - 4.5 28 150 DFN3X3
AON7474A SMD N 15.5 75 16 1.6 7.5 0.13 - 3.5 30 150 DFN3X3
AOTF2210L PTH N 36.5 200 20 2.5 13 0.09 - 60 74 175 TO-220F
AOTF256L PTH N 33 150 20 2.8 12 0.085 - 5 61.5 175 TO-220F
AOTF454L PTH N 41 150 20 4.6 13 0.094 - 5.5 70 150 TO-220FL
AP09T10GH SMD N 12.5 100 20 3 4.4 0.3 - 8 30 150 TO-252
AP09T10GH-HF SMD N 12.5 100 20 - 4.4 0.3 - 8 30 150 TO-252
AP09T10GP-HF PTH N 12.5 100 20 - 4.4 0.3 - 8 30 150 TO-220
AP10TN135H SMD N 20.8 100 20 3 8.1 0.135 - 8 27 150 TO-252
AP10TN135J PTH N 20.8 100 20 3 8.1 0.135 - 8 27 150 TO-251
AP10TN135JB PTH N 20.8 100 20 3 8.1 0.135 - 8 27 150 TO-251S
AP10TN135P PTH N 20.8 100 20 3 8.1 0.135 - 8 27 150 TO-220
AP15T15GH SMD N 44.6 150 20 3 11.2 0.15 - 12 80 150 TO-252
AP15T15GH-HF SMD N 44.6 150 20 - 11.2 0.15 - 12 80 150 TO-252
AP15T15GI-HF PTH N 31.3 150 20 - 10 0.15 - 12 80 150 TO-220F
AP15T25H-HF SMD N 62.5 250 20 4 8.7 0.32 - 10 85 150 TO-252
AP16T10GH SMD N 25 100 20 3 7.5 0.185 - 20 35 150 TO-252
AP18T10AGH-HF SMD N 27.8 100 20 - 9 0.16 - 10 55 150 TO-252
AP18T10AGJ-HF PTH N 27.8 100 20 - 9 0.16 - 10 55 150 TO-251
AP18T10GH SMD N 28 100 20 3 9 0.16 - 10 55 150 TO-252
AP18T10GH-HF SMD N 28 100 20 - 9 0.16 - 10 55 150 TO-252
AP18T10GI PTH N 28 100 20 - 9 0.16 - 10 55 150 TO-220F
AP18T10GJ PTH N 28 100 20 3 9 0.16 - 10 55 150 TO-251
AP18T10GJ-HF PTH N 28 100 20 - 9 0.16 - 10 55 150 TO-251
AP18T10GP PTH N 28 100 20 3 9 0.16 - 10 55 150 TO-220
AP6N100H SMD N 12.5 60 20 3 7.5 0.1 - 11 32 150 TO-252
AP6N100J PTH N 12.5 60 20 3 7.5 0.1 - 11 32 150 TO-251
AP6N100JV PTH N 12.5 60 20 3 7.5 0.1 - 11 32 150 TO-251VS
AP9871GH-HF SMD N 12.5 60 20 - 9.6 0.072 - 16 40 150 TO-252
AP9973GH-HF SMD N 27 60 20 - 14 0.08 - 15 77 150 TO-252
AP9973GI PTH N 25 60 20 - 14 0.08 - 15 77 150 TO-220CFM
AP9973GJ-HF PTH N 27 60 20 - 14 0.08 - 15 77 150 TO-251
AP9973GP PTH N 27 60 20 - 14 0.08 - 15 77 150 TO-220
AP9973GS SMD N 27 60 20 - 14 0.08 - 15 77 150 TO-263
AP9977AGH SMD N 12.5 60 20 3 9 0.1 - 12 35 150 TO-252
AP9977AGH-HF SMD N 12.5 60 20 3 9 0.1 - 12 35 150 TO-252
AP9977GH-HF SMD N 21 60 25 - 11 0.1 - 11 55 150 TO-252
AP9977GJ-HF PTH N 21 60 25 - 11 0.1 - 11 55 150 TO-251
AP9987GH-HF SMD N 34.7 80 25 - 15 0.09 - 12 75 150 TO-252
AP9987GJ-HF PTH N 34.7 80 25 - 15 0.09 - 12 75 150 TO-251
AP9995GH-HF SMD N 20.8 90 20 - 7 0.24 - 7.5 40 150 TO-252
AP9995GJ-HF PTH N 20.8 90 20 - 7 0.24 - 7.5 40 150 TO-251
AP9997AGH-HF SMD N 34.7 120 20 - 8.8 0.185 - 13.5 55 150 TO-252
AP9997BGH-HF SMD N 27.8 100 30 - 9.3 0.145 - 10 55 150 TO-252
AP9997BGJ-HF PTH N 27.8 100 30 - 9.3 0.145 - 10 55 150 TO-251
AP9997GH-HF SMD N 34.7 100 20 - 11 0.12 - 17 65 150 TO-252
AP9997GJ-HF PTH N 34.7 100 20 - 11 0.12 - 17 65 150 TO-251
AP9997GP PTH N 34.7 100 20 3 11 0.12 - 17 65 150 TO-220
AP9997GP-HF PTH N 34.7 100 20 - 11 0.12 - 17 65 150 TO-220
APM1105NU SMD N 60 100 20 2.5 16 0.1 - 10 80 175 TO-252
APM1110NU SMD N 60 100 20 3 10 0.175 - 10 36 175 TO-252
APM1110NUB PTH N 60 100 20 3 10 0.175 - 10 36 175 TO-251
APM6055NU SMD N 50 60 20 3 18 0.1 - 9 40 150 TO-252
BUK452-100B PTH N 60 100 30 4 10 0.3 - 25 90 175 TO-220AB
BUK472-100A PTH N 22 100 30 4 6.6 0.25 - 25 90 150 SOT-186A
BUK472-100B PTH N 22 100 30 4 6.1 0.3 - 25 90 150 SOT-186A
BUK76150-55A SMD N 36 55 20 4 11 0.15 5.5 26 40 175 D2PAK
BUK7Y113-100E SMD N 45 100 20 4 12 0.113 10.4 5.9 72 175 LFPAK56
BUK7Y153-100E SMD N 37.3 100 20 4 9.4 0.153 9.4 4.8 62 175 LFPAK56
BUK7Y72-80E SMD N 45 80 20 4 16 0.072 9.8 4 77 175 LFPAK56
BUK7Y98-80E SMD N 37 80 20 4 12.3 0.098 8.5 3.5 56 175 LFPAK56
CEB13N10 SMD N 65 100 20 - 12.8 0.18 - 8 85 175 TO-263
CEB13N10L SMD N 65 100 20 - 12.8 0.175 - 4 90 175 TO-263
CED12N10 PTH N 43 100 20 - 11 0.18 - 7 90 175 TO-251
CED12N10L SMD N 43 100 20 - 11 0.175 - 4 90 175 TO-252
CEP13N10 PTH N 65 100 20 - 12.8 0.18 - 8 85 175 TO-220
CEP13N10L PTH N 65 100 20 - 12.8 0.175 - 4 90 175 TO-220
CEU12N10 SMD N 43 100 20 - 11 0.18 - 7 90 175 TO-252
CEU12N10L SMD N 43 100 20 - 11 0.175 - 4 90 175 TO-252
CHM12N10PAGP SMD N 43 100 20 4 11 0.18 8 7 90 150 TO-252
CS630_A3H PTH N 83 200 30 - 9 0.28 - 21 90 150 TO-251
CS630_A4H SMD N 83 200 30 - 9 0.28 - 21 90 150 TO-252
CS630_A8H PTH N 83 200 30 - 9 0.28 - 21 90 150 TO-220AB
CS630A3H PTH N 83 200 30 4 9 0.28 13 21 90 150 TO-251
CS630A4H SMD N 83 200 30 4 9 0.28 13 21 90 150 TO-252
CS630A8H PTH N 83 200 30 4 9 0.28 13 21 90 150 TO-220AB
CS630F_A9H PTH N 30 200 30 - 9 0.28 - 21 90 150 TO-220F
CS630FA9H PTH N 30 200 30 4 9 0.28 13 21 90 150 TO-220F
FDB2670 SMD N 93 200 20 4.5 19 0.13 - 5 71 175 TO-263
FDD107AN06LA0 SMD N 25 60 20 3 10.9 0.091 - 54 45 175 TO-252AA
FDD6632 SMD N 15 30 20 3 9 0.07 - 41 73 175 TO-252AA
FDP120AN15A0 PTH N 65 150 20 4 14 0.12 - 16 85 175 TO-220AB
FDP2670 PTH N 93 200 20 4.5 19 0.13 - 5 71 175 TO-220
FQB13N06TM SMD N 45 60 25 4 13 0.135 5.8 25 90 175 D2PAK
FQB7N10LTM SMD N 40 100 20 2 7.3 0.35 4.6 100 55 175 D2PAK
FQB9N08LTM SMD N 40 80 20 2 9.3 0.21 4.7 180 70 175 D2PAK
FQB9N08TM SMD N 40 80 25 4 9.3 0.21 5.9 28 70 175 D2PAK
FQD13N06TF SMD N 28 60 25 4 10 0.14 5.8 25 90 150 DPAK
FQD13N06TM SMD N 28 60 25 4 10 0.14 5.8 25 90 150 DPAK
FQD7N10LTF SMD N 25 100 20 2 5.8 0.35 4.6 100 55 150 DPAK
FQD7N10LTM SMD N 25 100 20 2 5.8 0.35 4.6 100 55 150 DPAK
FQD7N10TM SMD N 25 100 25 4 5.8 0.35 5.8 24 60 150 DPAK
FQI13N06TU PTH N 45 60 25 4 13 0.135 5.8 25 90 175 I2PAK
FQI7N10LTU PTH N 40 100 20 2 7.3 0.35 4.6 100 55 175 I2PAK
FQI7N10TU PTH N 40 100 25 4 7.3 0.35 5.8 24 60 175 I2PAK
FQI9N08LTU PTH N 40 80 20 2 9.3 0.21 4.7 180 70 175 I2PAK
FQI9N08TU PTH N 40 80 25 4 9.3 0.21 5.9 28 70 175 I2PAK
FQP13N06 PTH N 45 60 25 4 13 0.135 5.8 25 90 175 TO-220
FQP7N10 PTH N 40 100 25 4 7.3 0.35 5.8 24 60 175 TO-220
FQP7N10L PTH N 40 100 20 2 7.3 0.35 4.6 100 55 175 TO-220
FQP9N08 PTH N 40 80 25 4 9.3 0.21 5.9 28 70 175 TO-220
FQP9N08L PTH N 40 80 20 2 9.3 0.21 4.7 180 70 175 TO-220
FQPF13N06 PTH N 24 60 25 4 9.4 0.135 5.8 25 90 175 TO-220F
FQPF7N10 PTH N 23 100 25 4 5.5 0.35 5.8 24 60 175 TO-220F
FQPF7N10L PTH N 23 100 20 2 5.5 0.35 4.6 100 55 175 TO-220F
FQPF9N08 PTH N 23 80 25 4 7 0.21 5.9 28 70 175 TO-220F
FQPF9N08L PTH N 23 80 20 2 7 0.21 4.7 180 70 175 TO-220F
FQU13N06TU PTH N 28 60 25 4 10 0.14 5.8 25 90 150 IPAK
FQU7N10LTU PTH N 25 100 20 2 5.8 0.35 4.6 100 55 150 IPAK
FTK1090 PTH N 42 100 20 - 15 0.09 - 9.5 59 175 TO-220AB
FTK15N10D SMD N 39 100 20 - 15 0.09 - 31 58 175 TO-252
G2009 PTH N 55 200 20 - 9 0.3 - 11 90 150 TO-251
G2009K SMD N 55 200 20 - 9 0.3 - 11 90 150 TO-252
HAT2189WP SMD N 20 200 30 - 8.5 0.27 - 24 86 150 WPAK
HRD13N10K SMD N 37 100 20 2.5 3.5 0.105 20 24 80 150 DPAK
HUF76609D3ST SMD N 49 100 16 3 10 0.16 13 41 75 175 TO-252AA
HUFA76609D3 PTH N 49 100 16 3 10 0.16 13 41 75 175 TO-251AA
HUFA76609D3S SMD N 49 100 16 3 10 0.16 13 41 75 175 TO-252AA
HUFA76609D3ST SMD N 49 100 16 3 10 0.16 13 41 75 175 TO-252AA
HY18N20D SMD N 48 200 30 3 18 0.092 - 8.6 55 150 TO-252
HY18N20T PTH N 57 200 30 3 18 0.092 - 8.6 55 175 TO-220AB
IRF200B211 PTH N 80 200 20 4.9 12 0.17 - 9.5 62 175 TO-220AB
IRF630NLPBF PTH N 82 200 20 4 9.3 0.3 35 14 89 175 TO-262
IRF630NPBF PTH N 82 200 20 4 9.3 0.3 35 14 89 175 TO-220AB
IRF630NSPBF SMD N 82 200 20 4 9.3 0.3 35 14 89 175 TO-263
IRFB4019PBF PTH N 80 150 20 4.9 17 0.095 13 13 74 175 TO-220AB
IRFB4212PBF PTH N 60 100 20 5 18 0.0725 15 28 66 175 TO-220AB
IRFU120ZPBF PTH N 35 100 20 4 8.7 0.19 6.9 26 41 175 TO-251
IRLR120A SMD N 35 100 20 2 8.4 0.22 - 10 90 150 DPAK
IRLU014N PTH N 28 55 16 1 10 0.14 - 47 80 175 TO-251
IRLU014NPBF PTH N 28 55 16 1 10 0.14 - 47 80 175 TO-251
IRLU120A PTH N 35 100 20 2 8.4 0.22 - 10 90 150 IPAK
KDB2670 SMD N 93 200 20 4.5 19 0.13 27 5 71 175 TO-263
KHB019N20F1 PTH N 50 200 30 - 19 0.14 - 33 80 150 TO-220IS
KHB019N20F2 PTH N 50 200 30 - 19 0.14 - 33 80 150 TO-220IS
MDD1903RH SMD N 36.8 100 20 3 12.8 0.105 - 10.6 60 150 TO-252
MDD1904RH SMD N 35.8 100 20 3 10.8 0.14 - 3.6 51 150 TO-252
MDIS1903TH PTH N 36.8 100 20 3 12.8 0.105 - 10.6 60 150 TO-251VS
ME15N10 SMD N 34.7 100 20 3 14.7 0.1 - 33 58 150 TO-252
MSD20N10 SMD N 50 100 20 3.5 11 0.28 - 3.9 40 175 TO-252
MTB070N11J3 SMD N 46 110 20 - 15 0.081 - 39 62 150 TO-252
MTB080N15J3 SMD N 83 150 20 2.5 18 0.105 - 20.6 87 175 TO-252
MTB090N06I3 PTH N 25 60 20 - 15 0.07 - 17 22 175 TO-251
MTBA5N10J3 SMD N 35 100 30 - 10 0.13 - 4.5 31 150 TO-252
MTBA5N10V8 SMD N 18 100 20 - 7 0.133 - 4.5 30 150 DFN3X3
MTDA0N10J3 SMD N 60 100 20 - 16 0.08 - 15 55 175 TO-252
MTDA0N10L3 SMD N 10 100 20 - 7 0.077 - 15 55 150 SOT-223
MTE130N20FP PTH N 50 200 20 - 17 0.15 - 37 83 175 TO-220FP
MTE130N20KFP PTH N 50 200 20 - 17 0.134 - 31 85 175 TO-220FP
MTEA0N10J3 SMD N 60 100 20 - 16 0.083 - 15 54 175 TO-252
MTEB4N15J3 SMD N 25 150 30 - 6 0.253 - 8 33 175 TO-252
MTEB6N20J3 SMD N 50 200 30 - 8.3 0.3 - 12 42 150 TO-252
MTN3484J3 SMD N 44 100 20 - 16 0.1 - 7 61.3 150 TO-252
NDT15N10 SMD N 34.7 100 20 - 14.7 0.08 - 33 58 150 TO-252
NVD3055-150 SMD N 28.8 60 20 4 9 0.15 7.1 37.1 70 175 DPAK
NVD3055L170 SMD N 28.5 60 15 2 9 0.17 4.7 69 70 175 DPAK
P8010BD SMD N 46 100 20 - 15 0.085 - 48 68 150 TO-252
P8010BIS PTH N 46 100 20 - 15 0.085 - 48 68 150 TO-251
PA110BDA SMD N 50 100 20 - 15 0.105 - 15 52 150 TO-252
PA410BD SMD N 35 100 20 - 10 0.14 - 60 50 150 TO-252
PB210BD SMD N 41 100 20 - 10 0.23 - 330 80 150 TO-252
PB210BI PTH N 36 100 20 - 9 0.23 - 20 46 150 TO-251
PC015BD SMD N 25 150 20 - 6 0.3 - 21 40 150 TO-252
PD504BA SMD N 46 110 20 - 15 0.085 - 50 68 150 TO-252
PHB11N06LT SMD N 33 55 15 2 10.3 0.13 - 64 55 175 D2PAK
PHD16N03T SMD N 32.6 30 20 4 13.1 0.1 - 45 85 175 DPAK
PHU11NQ10T PTH N 57.7 100 20 4 10.9 0.18 - 23 60 175 IPAK
PSMN075-100MSE SMD N 65 100 20 4 18 0.071 16.4 5.8 66 175 LFPAK33
QM0004D SMD N 34.7 100 20 2.5 12 0.112 26.2 8.2 60 150 TO-252
QM0004U PTH N 34.7 100 20 2.5 12 0.112 26.2 8.2 60 150 TO-251
QM0008D SMD N 20.8 100 20 2.5 5.4 0.31 9.6 30.6 29 150 TO-252
QM0008U PTH N 20.8 100 20 2.5 5.4 0.31 9.6 30.6 29 150 TO-251
QM6008U PTH N 20.8 60 20 2.5 10 0.09 4.9 7.4 38 150 TO-251
QM8014U PTH N 31.3 80 20 2.5 11.8 0.1 18.6 25 60 150 TO-251
RCD075N19 SMD N 20 190 20 2.5 7.5 0.336 30 14 60 150 SC-63
RCD075N20 SMD N 20 200 30 - 7.5 0.25 - 22 55 150 CPT3
RCD080N25 SMD N 20 250 30 - 8 0.225 25 40 80 150 CPT3
RCD080N25TL SMD N 20 250 30 5 8 0.3 25 40 80 150 SC-63
RCJ100N25 SMD N 40 250 30 5 10 0.32 26.5 40 75 150 SC-83
RCJ120N20 SMD N 40 200 30 5.25 12 0.325 15 33 57 150 SC-83
RCX051N25 PTH N 30 250 30 5.5 5 0.136 8.5 16 30 150 TO-220FM
RCX100N25 PTH N 40 250 30 5 10 0.32 26.5 40 75 150 TO-220FM
RSD050N06 SMD N 15 60 20 - 5 0.078 - 17 90 150 CPT3
RSD050N06FRA SMD N 15 60 20 3 5 0.109 8 17 90 150 SC-63
RSD050N06TL SMD N 15 60 20 3 5 0.109 8 17 90 150 SC-63
RSD050N10 SMD N 15 100 20 - 5 0.135 - 15 50 150 CPT3
RSD050N10FRA SMD N 15 100 20 2.5 5 0.19 14 15 50 150 SC-63
RSD080N06FRA SMD N 15 60 20 2.5 8 0.08 9.4 13 90 150 SC-63
RSD100N10 SMD N 20 100 20 - 10 0.095 - 17 65 150 CPT3
RSD100N10FRA SMD N 20 100 20 2.5 10 0.133 18 17 65 150 SC-63
RSD175N10 SMD N 20 100 20 - 17.5 0.075 24 25 85 150 CPT3
RSD175N10FRA SMD N 20 100 20 2.5 17.5 0.105 24 25 85 150 SC-63
RU1HE12L SMD N 40 100 20 2.7 12 0.16 - 14 75 175 TO-252
RU1HE16L SMD N 50 100 20 2.7 16 0.09 - 13 70 175 TO-252
SID05N10 PTH N 20 100 20 - 5 0.17 - 9.4 38 150 TO-251
SM1105NSUB PTH N 60 100 20 2.5 16 0.1 21 10 80 150 TO-251
SM1A10NSU SMD N 60 100 20 3 10 0.175 9.5 10 35 175 TO-252
SM1A18NSQG SMD N 17.8 100 20 - 9.2 0.1 - 9 60 150 DFN3X3D-8
SM1A23NSU SMD N 44 100 20 - 15 0.1 - 6 45 150 TO-252
SM1A24NSKP SMD N 26 100 20 - 10 0.126 - 7 36 150 DFN5X6-8
SM1A24NSU SMD N 36 100 20 - 12 0.12 - 7 36 150 TO-252
SM1A25NSU SMD N 29 100 20 - 10 0.162 - 7 30 150 TO-252
SM1A25NSUB PTH N 29 100 20 - 10 0.162 - 7 30 150 TO-251
SM1A28NSUB PTH N 50 100 30 - 17 0.076 - 5 60 150 TO-251
SM1A30NSU SMD N 50 100 20 - 18 0.07 - 7 60 150 TO-252
SM1F08NSU SMD N 54 150 25 - 14 0.11 - 6 70 150 TO-252
SM2A08NSU SMD N 54 200 25 - 10 0.21 - 6 55 150 TO-252
SM2A16NSF PTH N 78 200 25 - 15 0.156 - 4.4 71 150 TO-220
SM2A16NSFP PTH N 78 200 25 - 15 0.156 - 4.4 71 150 TO-220FP
SM2F04NSU SMD N 73 250 25 - 10 0.3 - 7 55 150 TO-252
SPN09T10 SMD и PTH N 40 100 20 3 14 0.16 10 10 56 150 TO-252,TO-263,TO-251
SPN11T10 SMD и PTH N 40 100 20 3 16 0.12 13 17 65 150 TO-252,TO-251
SQD07N25-350H SMD N 71 250 30 3.5 7 0.35 19 8 88 175 TO-252
SSF1090A SMD N 41.7 100 20 - 15 0.09 - 36.5 72 175 D2PAK
SSF1090D SMD N 39 100 20 - 15 0.09 - 31 58 175 DPAK
SSF1502G5 SMD N 12 150 20 - 6 0.2 - 5.7 47 175 SOT-223
SSM9973GJ PTH N 27 60 20 3 14 0.08 8 15 77 150 TO-251
SSM9977GH SMD N 21 60 25 3 11 0.09 6 11 55 150 TO-252
SSM9977GJ PTH N 21 60 25 3 11 0.09 6 11 55 150 TO-251
SSM9987GH SMD N 34.7 80 25 3 15 0.09 11 12 75 150 TO-252
STB16NF06LT4 SMD N 45 60 16 1 16 0.1 7.3 37 72 175 D2PAK
STD10NF10-1 PTH N 50 100 20 4 13 0.13 15.3 25 70 175 IPAK
STD10NF10T4 SMD N 50 100 20 4 13 0.13 15.3 25 70 175 DPAK
STD12NF06-1 PTH N 30 60 20 4 12 0.1 10 18 70 175 IPAK
STD12NF06L-1 PTH N 30 60 16 2 12 0.1 7.5 35 75 175 IPAK
STD12NF06LT4 SMD N 30 60 16 2 12 0.1 7.5 35 75 175 DPAK
STD6NF10T4 SMD N 30 100 20 4 6 0.25 10 10 45 175 DPAK
SUM09N20-270 SMD N 60 200 20 4 9 0.27 11 35 75 175 TO-263
SUU09N10-76P PTH N 32.1 100 20 4 9 0.076 12.7 11 71 150 TO-251
UT12N10 SMD и PTH N 43 100 20 - 12 0.15 - 7 90 150 TO-251,TO-252